An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure/temperature.
YYK Series is a standard type Autoclave used for removing the residual air bubbles after affixing polarizer in LED production.
No temperature overshoot.
Precision temperature uniformity available.
Adjustable air suction and exhaust speed.
Customized chamber dimensions.
4 step working procedures:
(1) Preheat: temperature rising, no pressurizing
(2) Pressurizing: holding temperature, pressurizing
(3) Deaeration: holding temperature, deaerating
(4) End: temperature cooling, pressure dropping
Safety features:
Door open / close detection, door lock / unlock detection, higher pressure alarm, air inlet pressure detection, safety valve, independent overheat protector, ELB to prevent over-current.
|
YYK500
|
YYK750
|
YYK800
|
YYK900
|
Method
|
Heating + pressurizing
|
|||
Specifications
|
Class-1 pressure container (AQSIQ pressure container verification)
|
|||
Operating temperature range
|
Room temp. 10~70°C
|
|||
Operating pressure range
|
0.101~0.9MPa
|
|||
Temperature distribution accuracy
|
±3°C (at 50°C)
|
|||
Max. temperature reaching time
|
Within 15min (adjustable)
|
|||
Max. pressure reaching time
|
Within 20min (adjustable)
|
|||
Max. operating pressure
|
0.9MPa
|
|||
Hydraulic test pressure
|
1.35MPa
|
|||
Material
|
SUS304 stainless steel, internal polishing
|
|||
Air suction port
|
15A (internally equipped with air filter and oil mist separator)
|
|||
Air exhaust port
|
20A (manual and auto exhaust, equipped with silencer)
|
|||
Medium
|
Dry air (pressure: working pressure +0.05MPa or higher)
|
|||
Opening / closing system
|
Manual clutch easy to operate
|
|||
Temperature control system
|
PID control
|
|||
Stirring system
|
Stirred by centrifugal fan (Water-Cooling is not required for shaft seal, free-maintenance)
|
|||
Pressurizing system
|
Controlled by pressure controller
|
|||
Control system
|
PLC control
|
|||
Timer
|
Time range: 99 hr 59min, Digital setting and display
|
|||
Sensor
|
5 groups of K thermocouple output terminals
|
|||
Pressure gauge
|
Pressure range: 0 to 1.0MPa, accuracy: ±1% (with upper limit alarm contact)
|
|||
Temp. controller
|
Digital setting and display, PID control
|
|||
Pressure controller
|
Digital setting and display, ON/OFF control
|
|||
Safety device
|
Door open / close detection, door lock / unlock detection, higher pressure alarm, air inlet pressure detection, safety valve, motor
overheating protection, independent overheat protector, ELB to prevent over-current
|
|||
External dimensions WxDxH
|
1000×1656×1546 mm
|
1200×1957×1781mm
|
1250×2057×1806 mm
|
1400×1950×2232 mm
|
Internal capacity
|
850L
|
1100L
|
1100L
|
1300L
|
Power supply (50/60 Hz)
|
3 phase AC380V 7A
|
3 phase AC380V 8A
|
3 phase AC380V 9A
|
3 phase AC380V 12A
|
Weight
|
~700kg
|
~900kg
|
~1000kg
|
~1300kg
|